Autoclave Machine, 280 Liter
$52.29
$72.16
AUTOCLAVE FULL AUTOMATIC WITH DRYING SPECIFICATION The Autoclave (Full automatic with drying) this sterilizer uses saturated steam as a sterilizing medium. The unit calibrated to reach (121°c). Once the maximum pressure is obtaining the heater will automatically shut-off (it will be indicted at the pilot light indicator for heat when it turns off) the pressure decreases, the heating system will automatically turn on again, it is fully automated in all processes by means of micro processors. If trouble takes place: The safety valve is calibrated to 28 PSI, in case the main control malfunction and the heating system will continue to generate, as the pressure gauge reach 30 PSI the “SAFETY VALVE” automatically exhaust the excess heat to avoid over heating of chamber and the whole system. TABLE OF SPECIFICATION OVERALL SIZE 29” x 53” x 71” CHAMBER / Liters 280 Liters OPERATION TEMPERATURE 121°c DISPLAY 6 Light Indicator, 1Digital Timer, Switch & Buzzer POWER SOURCE 9,000 watts NET WEIGHT 200 kg OPERATING INSTRUCTION FULL AUTOMATIC WITH DRYING FILL WITH WATER: TO FILL WITH WATER: Open the water supply valve. Fill water until it reaches the green line at glass tubing. Close the water supply valve, steam supply and exhaust valve. Load the instrument to the autoclave chamber for sterilization process. Close the door tightly. Set the Master Timer to 70 minutes, Sterilization Timer set to 60 minutes and Drying Timer set to 8 minutes. Turn on the switch; the pilot light indicator and the heater pilot light indicator will automatically light on. Intended Use / Purpose – Autoclave Machine 280 Liter The Autoclave Machine (280 Liter) is intended to sterilize large volumes of medical instruments, equipment, and materials using high-pressure saturated steam, ensuring complete elimination of microorganisms including bacteria, viruses, fungi, and spores. NOTE: Be sure that the entire light valve must be closed except the upper and the lower glass tubing valve. Sterilization cycle will automatically begin after approximately 22 minutes pre-heating time. The pressure gauge “JACKET” will start to go up, this heater pilot light indicator will automatically turn off when it reaches 28Psi, the steam from jacket automatically goes to “CHAMBER” with the sterile time will start, after the set time for sterilization, the drying cycle will automatically proceed. Buzzer sound to indicator completion of sterilization process and the pressure will automatically release. Turn-off the power switch. Open the door slightly. EAN: 4800000124760Product ID: 12476 SKU: PMS74268 Categories: Autoclave & Sterilizers, Clinic Hospital Equipment
Clinic Hospital Equipment